ACDC-100 TRMS
ACDC-100
Versatile AC/DC Clamp-on
Multimeter Series
Users Manual
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
Zobrazit stránku 0
1 2 3 4 5 6 ... 15 16

Shrnutí obsahu

Strany 1 - ACDC-100

ACDC-100 TRMS ACDC-100Versatile AC/DC Clamp-on Multimeter SeriesUsers Manual99 Washington Street Melrose, MA 02176 Phone 781-665-1400Toll Free 1-800-5

Strany 2

9Turn off power to the circuit being measured. 3. Free at least one end of the diode from the circuit. 4. Connect the test probes across the diode not

Strany 3

10SPECIFICATIONSGeneral SpecificationsDisplay: 3-3/4 digits 4000 counts LCD displayUpdate Rate: 3 per second nominalPolarity: AutomaticPower Supp

Strany 4

11Electrical (23 °C ± 5 °C) < 75% RHDC VoltageRANGE Accuracy400.0 mV ± (0.3% + 3dgts)4.000V, 40.00V, 400.0V ± (0.5% + 3dgts)600V ± (1.0% + 4dgts)R

Strany 5 - ACDC-100 TRMS / ACDC-100

12CapacitanceRANGE 1)Accuracy 2) 3)500.0 nf, 5.000 µf, 50.00 µf, 500.0 µf, 3000 µf ± (3.5% + 6dgts)Resolution: 0.1 nf on 500.0 nf range1) Additional 5

Strany 6 - Warnings and Precautions

13 Figure 1. — DC Voltage and AC Voltage functions

Strany 7

14 Figure 2. — ACA & DCA Current clamp-on function

Strany 8

15 Figure 3. — Resistance, Continuity, Capacitance and Diode functionsFigure 4. — Battery replacement

Strany 9

1EnglishACDC-100 TRMS ACDC-100Versatile AC/DC Clamp-on Multimeter SeriesUsers ManualACDC100_Rev002© 2010 Amprobe Test Tools.All rights reserved.

Strany 10

2Limited Warranty and Limitation of LiabilityYour Amprobe product will be free from defects in material and workmanship for 1 year from the date of pu

Strany 11

3 ➊ Hall-effect Clamp Jaw for AC & DC current electric field pick up ➋ Hand/Finger Barrier to indicate the limits of safe access of the meter durin

Strany 12

4ACDC-100 TRMS / ACDC-100 Versatile AC/DC Clamp-on Multimeter SeriesCONTENTSSymbols ...

Strany 13

5SYMBOLSBatteryRefer to the manualDouble insulatedDangerous VoltageDirect CurrentEarth GroundAlternating CurrentAudible toneConforms to relev

Strany 14

6Before and after hazardous voltage measurements, test the voltage function on a known •source such as line voltage to determine proper meter functio

Strany 15

7HOLD Press the HOLD button momentarily toggles to hold mode for all of the functions. To release the HOLD feature momentarily press the HOLD button.

Strany 16

8AC Current (see Fig. 2) Set the Function Switch to A1. position. Select AC current using the SELECT button. 2. Open spring-loaded clamp by pressin